CA3-B0-22-650-12A-D [Carling Technologies]

CIRC BRKR SWITCH LEVER 3P 50A;
CA3-B0-22-650-12A-D
型号: CA3-B0-22-650-12A-D
厂家: Carling Technologies    Carling Technologies
描述:

CIRC BRKR SWITCH LEVER 3P 50A

电路保护
文件: 总28页 (文件大小:4211K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
C-  
riesSeries  
C-Se  
CIRCUIT BREAKER  
The C-Series hydraulic-magnetic circuit breakers are ideal for applications that require higher amperage and  
voltage handling capability in a smaller package. They are available in 1-6 poles, 0.02-100amps, UL Recognized  
up to 480VAC or 150VDC, UL489 Listed up to 240VAC or 125VDC, with choice of time delays, terminal  
options, actuator styles and colors. The C-Series employs a unique arc chute design which allows for higher  
interrupting capacities of up to 10,000 amps. New thermoset glass filled polyester half shell construction  
provides for increased mechanical and electrical strength. The wiping contacts, mechanical linkage with two  
step actuaction, clean contacts providing high, positive contact pressure and longer contact life. Available with  
American Standard or Metric Threaded Stud terminals , or Saddle Clamp screw terminals. The optional mid-trip  
handle style actuator allows a visual indication of electrical overload with or without alarm feature.  
Eco-Friendly  
Resources:  
Download 3D CAD Files  
IGS  
STP  
Product Highlights:  
Š Extensive list of Agency Approvals  
Typical Applications:  
Š Marine  
Š Available with Standard or Metric Stud terminals, Š Telecom/Datacom  
or Saddle Clamp screw terminals  
Š Optional mid-trip handle style actuator  
Š Military  
Š Renewable Energy  
Š Unique arc chute design which allows for higher  
Š Generators & Welders  
interrupting capacities of up to 10,000 amps  
Š Exclusive Rockerguard and Push-To-Reset bezel  
Š Available with new solid color and two-color Visi-  
rocker® actuators  
Š New thermoset glass filled polyester half shell  
construction  
Carling Technologies, Inc.  
60 Johnson Avenue, Plainville, CT 06062  
Email: sales@carlingtech.com  
Application Support: team2@carlingtech.com  
Phone: 860.793.9281 Fax: 860.793.9231  
www.carlingtech.com  
|
2
C-Series – General Specifications  
Electrical Tables  
Table A: Lists UL Recognized & CSA Accepted configurations and performance capabilities as a Component Supplementary  
Protector  
C-SERIES TABLE A: COMPONENT SUPPLEMENTARY PROTECTORS  
SHORT CIRCUIT CAPACITY (AMPS)  
VOLTAGE  
CURRENT RATING  
APPLICATION CODES  
UL/CSA  
CIRCUIT  
CONFIGURATION  
NOTES  
WITH BACKUP  
FUSE 1  
MAX.  
RATING  
FULL LOAD  
AMPS  
GENERAL  
PURPOSE AMPS  
WITHOUT BACKUP  
FREQUENCY PHASE  
UL  
CSA  
FUSE  
32  
48  
65  
DC  
DC  
DC  
---  
---  
---  
0.02 - 100  
110 - 150  
0.02 - 70  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
5000  
5000  
5000  
5000  
7500  
7500  
10,000  
10,000  
5000  
5000  
5000  
3000  
5000  
5000  
5000  
3500  
3000  
1000  
5000  
3500  
5000  
---  
TC1, OL1, U2  
TC1, OL1, U2  
TC1, OL1, U2  
TC1, OL1, U2  
---  
---  
TC1,2, OL1,U1 TC1,2, OL1,U1  
TC1,2, OL0,U1 TC1,2, OL0,U1  
TC1,2, OL1,U1 TC1,2, OL1,U1  
TC1,2, OL0,U1 TC1,2, OL0,U1  
TC1,2, OL1,U1 TC1,2, OL1,U1  
TC1,2, OL0,U1 TC1,2, OL0,U1  
71 -100  
0.02 - 70  
---  
---  
80  
80  
DC  
DC  
---  
---  
71 -100  
0.02 - 70  
---  
---  
Must Have Agency Code "L"  
Must Have Agency Code "L"  
71 -100  
125  
125 / 250  
250  
DC  
DC  
DC  
---  
---  
---  
0.02 - 50  
0.02 - 50  
0.02 - 50  
0.02 - 100  
0.02 - 100  
---  
---  
TC1,2,OL1,U1  
TC1,2,OL1,U1  
TC1,2,OL1,U1  
TC1, OL1, U2  
TC1,2,OL1,U1  
TC1, OL0, U3  
TC1, OL0, U3  
TC1, OL1, U2  
TC1,2,OL1,U1  
TC1,2,OL1,U1  
TC1,2,OL1,U2  
TC1, OL1, U2  
TC1,2,OL1,U1  
TC1,2,OL1,C1  
TC1, OL0, U2  
TC1,2,OL1,C1  
TC1,2,OL0,U1  
TC1,2,OL1,C1  
TC1,2,OL1,C1  
TC1,2,OL0,C1  
TC1,2,OL1,C1  
TC1,2,OL0,C1  
TC1,2,OL1,U1  
TC1,2,OL1,U1  
TC1,2,OL1,U1  
TC1, OL1, U2  
TC1,2,OL1,U1  
---  
Must Have Agency Code "L"  
---  
Must Have Agency Code "L"  
---  
Must Have Agency Code "L". 2 Pole Break Required for 250 Volts  
Per Pole Rating  
---  
---  
---  
125  
50 / 60  
1
---  
Must Have Agency Code "L"  
150  
150  
DC  
DC  
---  
---  
80 - 100  
---  
Must Have Agency Code "L"  
---  
101 - 175  
---  
---  
Must Have Agency Code "L" Parallel Pole  
SERIES  
0.02 - 100  
0.02 - 50  
51 - 100  
0.02 - 100  
0.02 - 50  
0.02 - 100  
51 - 70  
---  
---  
---  
TC1, OL1, U2  
TC1,2,OL1,U1  
TC1,2,OL1,U1  
TC1,2,OL1,U2  
TC1, OL1, U2  
TC1,2,OL1,U1  
TC1,2,OL1,C1  
TC1, OL0, U2  
TC1,2,OL1,C1  
TC1,2,OL0,U1  
TC1,2,OL1,C1  
TC1,2,OL1,C1  
TC1,2,OL0,C1  
TC1,2,OL1,C1  
TC1,2,OL0,C1  
---  
---  
2 or 3 poles breaking single phase  
2 or 3 poles breaking single phase  
2 or 3 poles breaking single phase, "L" Agency Code  
Per Pole Rating  
125 / 250  
50 / 60  
1
---  
---  
---  
---  
---  
---  
1
3
---  
---  
Must Have Agency Code "L"  
---  
5000  
---  
250  
50 / 60  
0.02 - 100  
3000  
---  
0.02 - 70  
---  
---  
0.02 - 90  
---  
5000  
---  
3 poles breaking 3 phase  
5000  
---  
Must Have Agency Code "L"  
277  
50 / 60  
50 / 60  
1
3
0.02 - 50  
0.02 - 30  
---  
5000  
5000  
5000  
5000  
5000  
---  
---  
---  
3 poles breaking 3 phase  
2 poles breaking 1 phase  
480 / 277  
31 - 50  
---  
---  
0.02 - 30  
---  
---  
480  
50 / 60  
1
31 - 50  
---  
---  
80  
DC  
---  
1
0.02 - 50  
0.02 - 50  
0.02 - 50  
0.02 - 50  
0.02 - 50  
0.02 - 50  
0.02 - 50  
0.02 - 50  
0.02 - 50  
0.02 - 50  
0.02 - 50  
0.02 - 30  
---  
7500  
3000  
3500  
3000  
3500  
3000  
---  
TC1,2, OL1,U1 TC1,2, OL1,U1  
125  
50 / 60  
---  
---  
TC1, OL1, U2  
TC1, OL1, U2  
TC1,2,OL1,U1  
TC1, OL1, U2  
TC1, OL0, U2  
TC1,2,OL1,C1  
TC1,2,OL1,C1  
TC1, OL1, U2  
TC1, OL1, U2  
TC1,2,OL1,U1  
TC1, OL1, U2  
TC1, OL0, U2  
TC1,2,OL1,C1  
TC1,2,OL1,C1  
Per Pole Rating  
---  
---  
2 or 3 poles breaking single phase  
2 or 3 poles breaking single phase  
125 / 250  
50 / 60  
1
1
3
---  
---  
DUAL COIL  
---  
---  
250  
50 / 60  
---  
---  
Per Pole Rating  
---  
5000  
5000  
---  
277  
80  
50 / 60  
DC  
1
---  
1
---  
---  
3 poles breaking 3 phase  
---  
7500  
---  
TC1,2, OL1,U1 TC1,2, OL1,U1  
277  
250  
50 / 60  
50 / 60  
---  
5000  
5000  
5000  
5000  
5000  
5000  
---  
TC1,2,OL1,C1  
TC1,2,OL1,C1  
TC1,2,OL1,C1  
TC1,2,OL0,C1  
TC1,2,OL1,C1  
TC1,2,OL0,C1  
TC1,2,OL1,C1  
TC1,2,OL1,C1  
TC1,2,OL1,C1  
TC1,2,OL0,C1  
TC1,2,OL1,C1  
TC1,2,OL0,C1  
3
---  
---  
3 poles breaking 3 phase  
3 poles breaking 3 phase  
SHUNT  
RELAY  
---  
---  
480 / 277  
480  
50 / 60  
50 / 60  
3
1
31 - 50  
---  
---  
0.02 - 30  
---  
---  
2 poles breaking 1 phase  
31 - 50  
---  
---  
80  
DC  
---  
1
0.02 - 50  
0.02 - 50  
0.02 - 50  
0.02 - 70  
---  
7500  
---  
TC1,2, OL1,U1 TC1,2, OL1,U1  
277  
250  
50 / 60  
50 / 60  
---  
5000  
5000  
---  
TC1,2,OL1,C1  
TC1,2,OL1,C1  
3
---  
---  
TC1,2,OL1,C1  
TC1,2,OL1,C1  
3 poles breaking 3 phase  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
65  
80  
DC  
DC  
---  
---  
71 -100  
---  
---  
---  
0.02 - 70  
---  
---  
---  
71 -100  
---  
---  
---  
125  
50 / 60  
50 / 60  
1
1
1
3
1
0.02 - 100  
0.02 - 100  
0.02 - 100  
0.02 - 70  
0.02 - 50  
0.02 - 30  
---  
---  
---  
SWITCH ONLY  
125 / 250  
---  
---  
---  
2 or 3 poles breaking single phase  
3 poles breaking 3 phase  
---  
---  
---  
250  
277  
50 / 60  
50 / 60  
50 / 60  
---  
---  
---  
---  
---  
---  
---  
---  
---  
480 / 277  
3
31 - 50  
---  
---  
Notes for Table A:  
1
Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 15A minimum and no more than 4 times full load amps not to exceed 125A for 50 Amp or less rating and  
not to exceed 175 for 51 through 100 Amp rating  
*Manufacturer reserves the right to change product specification without prior notice.  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
C-Series – General Specifications  
3
Electrical Tables  
Table B: Lists UL Recognized and CSA Accepted configurations and performance capabilities as a Manual Motor Controller.  
RELAY  
Notes for Table B:  
1
UL recognized and CSA Accepted at 480V refers to 3 & 4 pole versions used in a 3Ø, wye connected circuit or 2-pole version connected with 2 poles breaking. 1Ø and backed up with  
series fusing as stated above in note 1.  
*Series, Shunt and Relay Trip - Voltage Coil Construction not current coils  
Table C: Lists UL Recognized, CSA Accepted , VDE and TUV Certified configurations and performance capabilities as a  
Component Supplementary Protector.  
Notes for Table C:  
1
2
General Purpose ratings for UL/CSA only.  
Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 15A minimum and no more than 4 times full load amps not to exceed 125A for 50 Amp or less rating and  
not to exceed 175 for 51 through 100 Amp rating.  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
4
C-Series – General Specifications  
Electrical Tables  
Table D: Lists UL Listed (489), CSA Certified (C22.2 No. 5.1-M) configuration and performance capabilities as a Molded Case  
Circuit Breaker.  
C SERIES TABLE D : UL489 LISTED BRANCH CIRCUIT BREAKERS  
INTERRUPTING  
CURRENT  
RATING  
VOLTAGE  
FREQUENCY  
DC  
CAPACITY  
(AMPS)  
CIRCUIT  
CONFIGURATION  
CONSTRUCTION NOTES  
MAX.  
FULL LOAD  
AMPS  
WITHOUT  
BACKUP FUSE  
PHASE  
---  
RATING  
50,0001  
10,000  
Limited to 2 Poles Max from 71 - 100 Amps.  
80  
0.10 - 100  
Limited to 2 Poles Max from 71 - 100 Amps.  
125  
DC  
DC  
---  
---  
0.10 - 100  
0.10 - 50  
0.10 - 50  
51 - 70  
5,000  
5,000  
1 - 3 Poles  
125 / 250  
1 or 2 Poles (2 Poles Required for 250 Volts)  
10,000  
5,000  
1 - 3 Poles  
120  
50 / 60  
50 / 60  
1
1
SERIES  
1 - 3 Poles  
0.10 - 50  
5,000  
2 or 3 Poles. 1 Pole of a 3 Pole Unit is Neutral  
120 / 240  
10000 1  
5,000  
2 or 3 Poles. 1 Pole of a 3 Pole Unit is Neutral  
0.10 - 50  
0.10 - 30  
0.10 - 20  
0.10 - 20  
0.10 - 30  
240  
240  
277  
120  
50 / 60  
50 / 60  
50 / 60  
50 / 60  
1
1
1
1
1Pole  
2 Pole  
1Pole  
---  
5,000  
10,000  
10,000  
DUAL COIL  
Notes from Table D:  
1
Special catalog number required. Consult factory.  
Table E: Lists UL Recognized, CSA Accepted configurations and performance capabilities as Protectors, Supplementary for  
Marine Electrical and Fuel Systems (Guide PEQZ2, File E75596). Ignition Protected per UL 1500. UL Classified Small Craft  
Electrical Devices, Marine in accordance with ISO 8846 (Guide UZMK, File MQ1515) as Marine Supplementary Protectors.  
Table F: Lists UL Listed configurations and performance capabilities as Circuit Breakers for use in Communications Equipment  
(Guide DITT, File E189195), under UL489A.  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
C-Series – General Specifications  
5
Electrical  
Mechanical  
Maximum Voltage  
AC, 480 WYE/277 VAC, 50/60 Hz  
(see Table A.)  
UL489: AC,240 VAC. (See Table D),  
50/60 Hz, 125 VDC  
Standard current coils: 0.100,  
0.250, 0.500, 0.750, 1.00, 2.50,  
5.00, 7.50, 10.0, 15.0, 25.0, 30.0,  
35.0, 40.0, 50.0, 60.0, 70.0, 80.0,  
90.0 and 100 amps. Other ratings  
available, see Ordering Scheme.  
Endurance  
10,000 ON-OFF operations @ 6 per  
minute; with rated current &  
voltage.  
Trip Free  
All C-Series circuit breakers will trip  
on overload, even when actuator is  
forcibly held in the ON position.  
The operating actuator moves  
positively to the OFF position when  
an overload causes the breaker to  
trip. With mid-trip, handle moves to  
the mid position on electrical trip of  
the circuit breaker. With mid trip  
handle with alarm switch, handle  
moves to the mid position and the  
alarm switch actuates when the  
circuit breaker is electrically  
tripped.  
Current Rating  
Trip Indication  
Standard Voltage Coils DC - 6V, 12V; AC - 120V; other  
ratings available, see Ordering  
Scheme.  
Auxiliary Switch Rating SPDT; 10.1 amps-250VAC, DC Aux.  
Switch 1.0A, 65 VDC. 0.5A,  
80VDC,1/4 HP, 125VAC,VDE & TUV  
1.0 125 VAC.  
Insulation Resistance  
Dielectric Strength  
Minimum of 100 Megohms at 500  
VDC.  
Physical  
UL, CSA: 1960 V 50/60 Hz for one  
minute between all electrically  
isolated terminals. C-Series Circuit  
Breakers comply with the 8mm  
spacing and 3750V 50/60 Hz  
dielectric requirements from  
hazardous voltage to operator  
accessible surfaces, between  
adjacent poles and from main  
circuits to auxiliary circuits per  
Publications EN 60950 and  
VDE 0805.  
Number of Poles  
1-6 poles ≤ 50A; 1-4 poles @ 51-  
70A; 1-2 poles 71-100A. UL489  
Handle: 1 pole ≤ 100A, 2 pole ≤  
50A; Rocker: 1 pole ≤ 100A.  
Internal Circuit Config. Series (with or without auxiliary  
switch, mid trip & mid trip with  
alarm switch) Shunt & Relay with  
current or voltage trip coils, Dual  
Coil, Switch Only (with or without  
aux. switch). UL489: Series (with or  
without auxiliary switch, mid-trip &  
midtrip with alarm switch).  
Resistance, Impedance Values from Line to Load Terminal -  
based on Series Trip Circuit  
Weight  
Standard Colors  
Approx.112 grams/pole ( 3.95 oz).  
Housing: Black  
RESISTANCE, IMPEDANCE VALUES  
Breaker.  
from Line to Load Terminals  
(Values Based on Series Trip Circuit Breaker)  
Environmental  
1000  
CURRENT  
(AMPS)  
TOLERANCE  
(%)  
Designed and tested in accordance with requirements of  
specification MIL-PRF-55629 & MIL-STD-202 as follows:  
100  
10  
0.10 - 5.0  
5.1 - 20.0  
15%  
25%  
35%  
Shock  
Withstands 100 Gs, 6ms sawtooth  
while carrying rated current per  
Method 213, Test Condition “I”.  
Instantaneous and ultrashort curves  
tested @ 90% of rated current.  
Withstands 0.060” excursion from  
10-55 Hz & 10 Gs 55-500 Hz, @  
rated current per Method 204C,  
Test Cond. A. Instantaneous &  
ultrashort curves tested @ 90% of  
rated current.  
Method 106D, i.e., ten 24-hour  
cycles @ +25°C to +65°C,  
80-98% RH.  
Method 101, Condition A (90-95%  
RH @ 5% NaCl Solution, 96 hrs).  
Method 107D, Condition A (five  
cycles @ -55°C to +25°C to +85°C  
to +25°C).  
O
H
M
S
20.1 - 100.0  
1
0.1  
0.01  
Vibration  
0.001  
0.01  
0.1  
1
10  
100  
AMPERE RATING  
Pulse Tolerance Curves  
60 Hz 1/2 Cycle  
Inrush Pulse Tolerance  
50 Hz 1/2 Cycle  
Moisture Resistance  
Inrush Pulse Tolerance  
I
I
r
r
Time Delay Curves  
Time Delay Curves  
42, 44  
& 46  
22x  
10x  
42, 44  
& 46  
(50 Amps Max.)  
(50 Amps Max.)  
25x  
12x  
Time Delay Curves  
Time Delay Curves  
22, 24 (100 Amps Max.)  
26 (70 Amps Max.)  
22, 24 (100 Amps Max.)  
26 (70 Amps Max.)  
Salt Spray  
t
t
10.0  
20.0  
5.0  
8.33  
16.67  
4.165  
Time in  
Milliseconds  
Thermal Shock  
Operating Temperature -40°C to +85°C  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
6
C-Series - Agency Certifications  
Agency Certifications:  
UL Recognized  
UL Standard 1077  
Component Recognition Program  
as Protectors, Supplementary  
(Guide CCN/QVNU2, File E75596)  
UL Standard 508  
UL Standard 1500  
Motor Controllers, Manual  
(Guide CCN/NLRV2, File E135367)  
Protectors, Supplementary for  
Marine Electrical & Fuel Systems  
(Guide PEQZ2, File E75596)  
Ignition Protection  
UL Listed  
UL Standard 489  
Circuit Breakers, Molded Case,  
(Guide DIVQ, File E129899)  
UL Standard 489A  
Communications Equipment  
(Guide CCN/DITT, File E189195)  
CSA Accepted  
Component Supplementary Protector  
under Class 3215 30,  
File 047848 0 000  
CSA Standard C22.2 No. 235  
CSA Certified  
Circuit Breaker Model Case  
(Class 1432 01, File 093910),  
CSA Standard C22.2 No. 5.1 - M  
TUV Certified  
VDE Certified  
EN60934, under License No.  
R72041016  
EN60934, VDE 0642 under File No.  
10537  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
C-Series Handle UL Recognized – Ordering Scheme  
7
C A 3 B 0 10 450 1 2 1 C  
8
9
10  
11  
Agency  
Approval  
1
2
3
4
5
6
7
Terminal  
Actuator  
Color  
Mounting  
Bezel/Barrier  
Series  
Actuator  
Poles  
Circuit  
Aux/Alarm  
Switch  
Frequency  
& Delay  
Current Rating  
7 CURRENT RATING (AMPERES)  
1 SERIES  
C
CODE AMPERES  
020 0.020  
025 0.025  
030 0.030  
035 0.035  
040 0.040  
045 0.045  
050 0.050  
055 0.055  
060 0.060  
065 0.065  
070 0.070  
075 0.075  
080 0.080  
085 0.085  
090 0.090  
095 0.095  
210 0.100  
215 0.150  
220 0.200  
225 0.250  
230 0.300  
235 0.350  
240 0.400  
245 0.450  
250 0.500  
255 0.550  
260 0.600  
265 0.650  
270 0.700  
275 0.750  
280 0.800  
285 0.850  
290 0.900  
295 0.950  
410 1.000  
512 1.250  
415 1.500  
517 1.750  
420 2.000  
522 2.250  
425 2.500  
527 2.750  
430 3.000  
614 14.000  
615 15.000  
616 16.000  
617 17.000  
618 18.000  
620 20.000  
622 22.000  
624 24.000  
625 25.000  
630 30.000  
635 35.000  
640 40.000  
650 50.000  
435 3.500  
440 4.000  
445 4.500  
450 5.000  
455 5.500  
460 6.000  
465 6.500  
470 7.000  
475 7.500  
480 8.000  
485 8.500  
490 9.000  
495 9.500  
610 10.000  
710 10.500  
611 11.000  
711 11.500  
612 12.000  
712 12.500  
613 13.000  
2 ACTUATOR1  
A
B
S
T
Handle, one per pole  
Handle, one per multipole unit  
Mid-Trip Handle, one per pole  
Mid-Trip, one per pole & Alarm Switch  
3 POLES2  
1
2
One  
Two  
3
4
Three  
Four  
5
6
Five  
Six  
9
660 60.000  
4 CIRCUIT3  
F
Relay Trip (current)  
Relay Trip (voltage)  
Dual Coil with Shunt Trip  
Voltage Coil  
Dual Coil with Relay Trip  
Voltage Coil  
9
4
670 70.000  
3
4
4,5  
A
B
C
D
Switch Only (no coil)  
G
H
9
680 80.000  
Series Trip (current)  
Series Trip (voltage)  
Shunt Trip (current)  
Shunt Trip (voltage)  
9
685 85.000  
9
690 90.000  
4
4
4,5  
K
9
695 95.000  
E
9
810 100.000  
VOLTAGE COIL (NOMINAL RATED VOLTAGE)7  
5 AUXILIARY/ALARM SWITCH  
CODE  
RATING  
0
2
3
4
without Aux Switch  
A06 6DC  
A12 12DC  
A18 18DC  
A24 24DC  
A32 32DC  
A48 48DC  
A65 65DC  
J06 6AC  
J12 12AC  
J18 18AC  
J24 24AC  
J48 48AC  
J65 65AC  
K20 120AC  
L40 240AC  
S.P.D.T., 0.110 Q.C. Term.  
S.P.D.T., 0.139 Solder Lug  
S.P.D.T., 0.110 Q.C. Term.  
(Gold Contacts)  
6
8
9
S.P.S.T., 0.139 Solder Lug  
S.P.S.T., 0.187 Q.C. Term.  
S.P.D.T., 0.187 Q.C. Term.  
6 FREQUENCY & DELAY  
8 TERMINAL15  
3
10  
12  
13,15  
15  
03  
10  
11  
12  
14  
16  
20  
21  
22  
24  
26  
DC 50/60Hz, Switch Only  
DC Instantaneous  
DC Ultra Short  
DC Short  
DC Medium  
DC Long  
50/60Hz Instantaneous  
50/60Hz Ultra Short  
50/60Hz Short  
50/60Hz Medium  
50/60Hz Long  
30  
31  
32  
34  
36  
42  
44  
46  
52  
54  
56  
DC 50/60Hz Instantaneous  
DC 50/60Hz Ultra Short  
DC 50/60Hz Short  
DC 50/60Hz Medium  
DC 50/60Hz Long  
50/60Hz Short, Hi-Inrush  
50/60Hz Medium, Hi-Inrush  
50/60Hz Long, Hi-Inrush  
DC Short, Hi-Inrush  
DC Medium, Hi-Inrush  
DC Long, Hi-Inrush  
1
2
3
4
5
Stud 10-32  
6
7
9
Stud M6  
7
11  
12  
11  
11  
Screw 10-32  
Stud 1/4-20  
Stud M5 x 0.8  
0.250 Double Click Connect  
7/16” Clip Terminal  
Plug-In Stud  
14  
11,15  
A
C
Screw M5 x 0.8  
5/16” Clip Terminal  
8
8
8
8
7
9 ACTUATOR COLOR & LEGEND16  
Actuator Color  
White  
Black  
Red  
Green  
Blue  
Yellow  
Gray  
I-O  
A
C
F
H
K
M
P
ON-OFF  
Dual  
Legend Color  
Black  
White  
White  
White  
White  
Black  
Black  
Black  
8
B
D
G
J
1
2
3
4
5
6
7
8
9
Notes:  
L
1
Actuator Code:  
N
Q
S
U
A: Handle tie pin spacer(s) and retainers provided assembled with multi-pole units.  
B: Handle location as viewed from front of breaker:  
Orange  
Black (short handle)  
R
T
2 pole - left pole 3 pole - center pole 4 pole - two handles at center poles  
17  
5 pole - three handles at center poles  
6 pole - four handles at center poles  
White  
S: Handle moves to mid-position only upon electrical trip of the breaker. Available  
with circuit codes B, C, D, E, F, G, H and K.  
T: Handle moves to mid-position and alarm switch activates only upon electrical trip  
of the breaker. Available with circuit codes B & C.  
10 MOUNTING/BARRIERS  
MOUNTING STYLE  
BARRIERS  
VOLTAGE  
2
Standard multipole units have all poles identical except when specifying auxiliary  
switch and/or mixed poles. 4 pole max w/VDE. 5th pole available as Series Trip w/  
Voltage Coil only.  
Threaded Insert  
1
6-32 x 0.195 inches  
6-32 X 0.195 inches  
6-32ꢀXꢀ0.195ꢀinchesꢀꢀ  
ISO M3 x 5mm  
ISO M3 x 5mm  
ISOꢀM3ꢀxꢀ5mmꢀꢀ  
no  
< 300  
< 300  
≥ꢀ300  
< 300  
< 300  
≥ꢀ300  
A
C
2
B
D
yes  
yesꢀꢀ  
no  
yes  
yesꢀꢀ  
3
Switch Only circuits, rated up to 50 amps and 6 poles, and only available with VDE  
Certificationꢀwhenꢀtiedꢀtoꢀaꢀprotectedꢀpoleꢀ(CircuitꢀCodeꢀB,ꢀC,ꢀDꢀorꢀH.).ꢀForꢀ.02ꢀtoꢀꢀ  
30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650.  
For 55-70 amps, select Current Code 670. For 75-100 amps, select Current Code 810.  
Circuit Codes D,E,F,G,H & K available with Terminal Codes 1,2,4 & 5 only. Circuit  
Codes D, F, H & K available up to 50 amps maximum Current Rating.  
Consult factory for available Dual Coil options, as special catalog number is  
required. Dual Coil Voltage Coils with Shunt Trip Construction trip instantaneously  
on line voltage. Dual Coil Voltage Coils require 30VA minimum power to trip  
instantaneously and are rated for intermittent duty only.  
Auxiliary Switch available with Series Trip and Switch Only circuits. On multi-pole  
breakers, one aux. switch is supplied, mounted in the extreme right pole.  
Voltage coils not rated for continuous duty. Available only with delay codes 10 & 20.  
Available with Circuit Codes B & D only, and up to 50 amps maximum.  
Current Ratings 60 - 70 are available up to four poles maximum. Ratings 71 - 100  
are available up to two poles maximum.  
18  
4
5
18  
Front panel Snap-In, 1.00” [25.4mm] wide bezel  
17  
E
with Handleguard  
no  
< 300  
6
11 AGENCY APPROVAL  
C
Dꢀ  
Eꢀ  
Hꢀ  
I
UL Recognized, CSA Accepted  
VDEꢀCertified,ꢀULꢀRecognized,ꢀCSAꢀAccepted  
TUVꢀCertified,ꢀULꢀRecognized,ꢀCSAꢀAccepted  
UL489ꢀConstruction:ꢀVDEꢀCertified,ꢀULꢀRecognized,ꢀCSAꢀꢀAccepted  
UL Rec. STD 1077, UL Rec. 1500 (ignition protected), CSA Accepted  
UL489 Construction: UL Recognized, CSA Accepted  
7
8
9
10 Terminal Code 1 available to 60 amps maximum.  
11 Terminal Codes 2, 4, 5 and C available to 50 amps maximum.  
12 Terminal Codes 3, 6 & 9 available to 100 amps maximum.  
13 Terminal Code 7 available to 25 amps maximum.  
14 Terminal Code A available to 100 amps maximum.  
15 Terminal Codes 7, 9 & C are not VDE approved.  
16 No marking available. Consult factory. VDE/TUV Approval requires dual  
(I-O, ON-OFF) or I-O markings on all handles.  
L
Rꢀ  
UL489ꢀConstruction:ꢀTUVꢀCertified,ꢀULꢀRecognized,ꢀCSAꢀAccepted  
17 Single pole only.  
18 VDE/TUV: 30 amps max.; UL/CSA: 50 amps max.; Available in 2 - 4 poles only  
and limited to AC Delays. “General Purpose amps” not rated for “full load amps” or  
to be used in applications with a motor.  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
8
C-Series Handle UL489A Listed / Parallel Pole – Ordering Scheme  
C A 2 P 0 D4 820 3 2 1 M T  
8
9
10  
Mounting  
11  
12  
1
2
3
4
5
6
7
Terminal  
Actuator  
Color  
Max. App. Agency  
Rating  
Series  
Actuator  
Poles  
Circuit  
Aux/Alarm  
Switch  
Frequency  
& Delay  
Current Rating  
Approval  
8 TERMINAL6  
1 SERIES  
3
6
A
Stud 1/4-20  
Stud M6  
C
Plug-In Stud  
2 ACTUATOR1  
A
S
T
Handle, one per pole  
Mid-Trip Handle, one per pole  
Mid-Trip, one per pole & Alarm Switch  
9 ACTUATOR COLOR2  
LEGEND  
ON-OFF  
Dual  
Legend Color  
Black  
White  
White  
White  
White  
Black  
Black  
Black  
White  
Black  
Red  
Green  
Blue  
Yellow  
Gray  
Orange  
B
D
G
J
1
2
3
4
5
6
7
8
3 POLES4  
1
One  
2
Two  
3
Three  
L
4 CIRCUIT5  
N
Q
S
B
Series Trip  
P
Series Trip (parallel pole)  
5 AUXILIARY/ALARM SWITCH  
0
2
3
4
without Aux Switch  
10 MOUNTING  
S.P.D.T., 0.110 Q.C. Term.  
S.P.D.T., 0.139 Solder Lug  
S.P.D.T., 0.110 Q.C. Term.  
(Gold Contacts)  
6
8
9
S.P.S.T., 0.139 Solder Lug  
S.P.S.T., 0.187 Q.C. Term.  
S.P.D.T., 0.187 Q.C. Term.  
Threaded Insert  
1
2
6-32 x 0.195 inches  
ISO M3 x 5mm  
11 MAXIMUM APPLICATION RATING  
80 DC  
6 FREQUENCY & DELAY7  
M
D1  
D2  
D4  
D6  
DC Ultra Short  
DC Short  
11  
12  
14  
16  
DC Ultra Short  
DC Short  
DC Medium  
DC Long  
DC Medium  
DC Long  
12 AGENCY APPROVAL8  
A
Without Approval  
Jꢀ  
T
Kꢀꢀ  
7ꢀ  
UL489AꢀListed,ꢀTUVꢀCertified  
UL489A Listed  
UL489AꢀListed,ꢀVDEꢀCertifiedꢀ(upꢀtoꢀ200ꢀamps)  
UL489AꢀListed,ꢀTUVꢀCertifiedꢀ(upꢀtoꢀ250ꢀamps)  
7 CURRENT RATING (AMPERES)  
CODE AMPERES  
810 100.00  
811 110.00  
812 120.00  
912 125.00  
813 130.00  
814 140.00  
815 150.00  
816 160.00  
817 170.00  
917 175.00  
818 180.00  
819 190.00  
820 200.00  
9224 225.00  
8254 250.00  
Notes:  
1
Handle moves to Mid-Position only upon electrical trip of C/B when Actuator S is  
specified.ꢀWhenꢀActuatorꢀCodeꢀTꢀisꢀspecified,ꢀhandleꢀmovesꢀtoꢀMidꢀPositionꢀandꢀꢀ  
Alarm Switch actuates only upon electrical trip of C/B.  
2
3
Standard Handle colors are White, Black, Red & Yellow.  
Breakers with Terminal Codes 3 & 6 are supplied with bus bars connecting the Line  
and Load Terminals. For Terminal Code A, Line and Load Terminals must be  
connected to a copper bus bar having a minimum cross-section of 0.078 square  
inches. Terminal code A not available on the single pole unit.  
Rating for 101 to 125 amps are available in 1 pole size. Ratings from 110 to 200  
amps are available in 2-pole size. For ratings from 225-250 amps, specify 3-pole size.  
Circuit code B only available with 1 pole.  
4
5
6
7
8
1 pole only available with terminal codes 3 and 6.  
Delays 11, 12, 14, and 16 are only available with 1 pole.  
Agency code K and 7 not available with 1 pole.  
Agency code J only available with 1 pole.  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
C-Series Rocker UL489A Listed / Parallel Pole – Ordering Scheme  
9
C 1 2 P 0 D4 820 3 1 A M T  
8
9
10  
Mounting  
11  
12  
1
2
3
4
5
6
7
Terminal  
Actuator  
Color  
Max. App. Agency  
Rating  
Series  
Actuator  
Poles  
Circuit  
Aux/Alarm  
Switch  
Frequency  
& Delay  
Current Rating  
Approval  
8 TERMINAL4  
1 SERIES  
C
3
6
A
Stud 1/4-20  
Stud M6  
Plug-In Stud  
2 ACTUATOR  
C
D
F
G
J
K
1
2
3
4
5
6
7
8
Curved Rocker, Two Color Visi, Indicate On, Vertical Legend  
Curved Rocker, Two Color Visi, Indicate On, Horizontal Legend  
Curved Rocker, Two Color Visi, Indicate Off, Vertical Legend  
Curved Rocker, Two Color Visi, Indicate Off, Horizontal Legend  
Curved Rocker, Single Color, Vertical Legend  
Curved Rocker, Single Color, Horizontal Legend  
Flat Rocker, Two Color Visi, Vertical Legend  
Flat Rocker, Two Color Visi, Horizontal Legend  
Flat Rocker, Single Color, Vertical Legend  
Flat Rocker, Single Color, Horizontal Legend  
Flat Rocker, Push To Reset, Two Color Visi, Vertical Legend  
Flat Rocker, Push To Reset, Two Color Visi, Horizontal Legend  
Flat Rocker, Push To Reset, Single Color, Vertical Legend  
Flat Rocker, Push To Reset, Single Color, Horizontal Legend  
9 ACTUATOR COLOR  
LEGEND  
ON-OFF  
B
D
G
J
Dual  
Legend Color  
Black  
White  
White  
White  
White  
Black  
Black  
Black  
White  
Black  
Red  
Green  
Blue  
Yellow  
Gray  
Orange  
1
2
3
4
5
6
7
8
L
N
Q
S
10 MOUNTING  
ROCKER / MOUNTING INSERT STYLE  
Standard Rocker Bezel - 6-32 Inserts  
Standard Rocker Bezel - M3 Inserts  
Rocker Guard Bezel - 6-32 Inserts  
Rocker Guard Bezel - M3 Inserts  
Standard Bezel with recessed Off Side Flat Rocker - 6-32 Inserts  
Standard Bezel with recessed Off Side Flat Rocker - M3 Inserts  
Push to Reset Bezel - 6-32 Inserts  
3 POLES2  
A
B
C
D
E
F
1
One  
2
Two  
3
Three  
4 CIRCUIT3  
B
Series Trip  
P
Series Trip (parallel pole)  
G
H
Push to Reset Bezel - M3 Inserts  
5 AUXILIARY/ALARM SWITCH  
0
2
3
4
without Aux Switch  
6
8
9
S.P.S.T., 0.139 Solder Lug  
S.P.S.T., 0.187 Q.C. Term.  
S.P.D.T., 0.187 Q.C. Term.  
S.P.D.T., 0.110 Q.C. Term.  
S.P.D.T., 0.139 Solder Lug  
S.P.D.T., 0.110 Q.C. Term.  
(Gold Contacts)  
11 MAXIMUM APPLICATION RATING  
80 DC  
M
12 AGENCY APPROVAL6  
A
Jꢀ  
T
Without Approval  
UL489AꢀListed,ꢀTUVꢀCertified  
UL489A Listed  
6 FREQUENCY & DELAY5  
D1  
D2  
D4  
D6  
DC Ultra Short  
DC Short  
11  
12  
14  
16  
DC Ultra Short  
DC Short  
DC Medium  
DC Long  
7ꢀ  
UL489AꢀListed,ꢀTUVꢀCertified  
DC Medium  
DC Long  
Notes:  
1
Breakers with Terminal Codes 3 & 6 are supplied with bus bars connecting the Line  
and Load Terminals. For Terminal Code A, Line and Load Terminals must be  
connected to a copper bus bar having a minimum cross-section of 0.078 square  
inches. Terminal code A not available on the single pole unit.  
Ratings for 101 to 125 amps are availabe in 1-pole size. Ratings from 110 to 200  
amps are available in 2-pole size. For ratings from 225-250 amps, specify 3-pole  
size.  
7 CURRENT RATING (AMPERES)2  
CODE AMPERES  
2
810 100.00  
811 110.00  
812 120.00  
912 125.00  
813 130.00  
814 140.00  
815 150.00  
816 160.00  
817 170.00  
917 175.00  
818 180.00  
819 190.00  
820 200.00  
922 225.00  
825 250.00  
3
4
5
6
Circuit code B only available with 1-pole.  
1 pole only available with terminal codes 3 and 6.  
Delays 11, 12, 14, and 16 are only available with 1 pole.  
Agency code K and 7 not available with 1 pole.  
Agency code J only available with 1 pole.  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
10  
C-Series Handle UL489 Listed – Ordering Scheme  
C A 3 B 0 14 450 1 2 1 K G  
8
9
10  
Mounting/  
Barriers  
11  
12  
1
2
3
4
5
6
7
Terminal  
Actuator  
Color  
Max. App. Agency  
Rating Approval  
Series  
Actuator  
Poles  
Circuit  
Aux/Alarm  
Switch  
Frequency  
& Delay  
Current Rating  
7 CURRENT RATING (AMPERES)5  
1 SERIES  
C
CODE AMPERES  
210 0.100  
215 0.150  
220 0.200  
225 0.250  
230 0.300  
235 0.350  
240 0.400  
245 0.450  
250 0.500  
255 0.550  
260 0.600  
265 0.650  
270 0.700  
275 0.750  
280 0.800  
285 0.850  
290 0.900  
295 0.950  
410 1.000  
512 1.250  
415 1.500  
517 1.750  
420 2.000  
522 2.250  
425 2.500  
527 2.750  
430 3.000  
435 3.500  
440 4.000  
445 4.500  
450 5.000  
455 5.500  
460 6.000  
465 6.500  
470 7.000  
475 7.500  
480 8.000  
485 8.500  
490 9.000  
495 9.500  
610 10.000  
710 10.500  
618 18.000  
620 20.000  
622 22.000  
624 24.000  
625 25.000  
630 30.000  
635 35.000  
640 40.000  
660 60.000  
670 70.000  
680 80.000  
685 85.000  
690 90.000  
695 95.000  
810 100.000  
2 ACTUATOR1  
A
B
S
T
Handle, one per pole  
Handle, one per multipole unit  
Mid-Trip Handle, one per pole  
Mid-Trip, one per pole & Alarm Switch  
611  
711  
11.000  
11.500  
3 POLES2  
1
One  
2
Two  
3
Three  
612 12.000  
712 12.500  
613 13.000  
614 14.000  
615 15.000  
616 16.000  
617 17.000  
4 CIRCUIT  
B
Series Trip (current)  
5 AUXILIARY/ALARM SWITCH3  
0
2
3
4
without Aux Switch  
8 TERMINAL6  
S.P.D.T., 0.110 Q.C. Term.  
S.P.D.T., 0.139 Solder Lug  
S.P.D.T., 0.110 Q.C. Term.  
(Gold Contacts)  
6
8
9
S.P.S.T., 0.139 Solder Lug  
S.P.S.T., 0.187 Q.C. Term.  
S.P.D.T., 0.187 Q.C. Term.  
17  
28  
39  
48  
58  
Stud 10-32  
Screw 10-32  
Stud 1/4-20  
Stud M5 x 0.8  
Screw M5 x 0.8  
69  
Stud M6  
7/16” Clip Terminal  
Plug-In Stud  
99  
A10  
C8  
5/16” Clip Terminal  
6 FREQUENCY & DELAY  
11  
12  
14  
16  
21  
22  
24  
DC Ultra Short  
DC Short  
DC Medium  
26  
50/60Hz Long  
424  
444  
464  
524  
544  
564  
50/60Hz Short, Hi-Inrush  
50/60Hz Medium, Hi-Inrush  
50/60Hz Long, Hi-Inrush  
DC Short, Hi-Inrush  
DC Medium, Hi-Inrush  
DC Long, Hi-Inrush  
9 ACTUATOR COLOR & LEGEND11  
Actuator Color  
White  
Black  
Red  
Green  
Blue  
Yellow  
Gray  
ON-OFF  
Dual  
Legend Color  
Black  
White  
White  
White  
White  
Black  
Black  
Black  
DC Long  
B
D
G
J
1
2
3
4
5
6
7
8
50/60Hz Ultra Short  
50/60Hz Short  
50/60Hz Medium  
L
Notes:  
N
Q
S
1
Actuator Code:  
A: Handle tie pin spacer(s) and retainers provided assembled with multi-pole units.  
B: Handle located, as viewed from front of breaker in left pole. 2 pole maximum.  
S: Handle moves to mid-position only upon electrical trip of the breaker.  
T: Handle moves to mid-position and alarm switch activates only upon electrical trip  
of the breaker.  
Orange  
10 MOUNTING/BARRIERS  
MOUNTING STYLE  
2
Standard multipole units have all poles identical except when specifying auxiliary  
switch and/or mixed poles.  
12  
BARRIERS  
Threaded Insert  
6-32 x 0.195 inches  
ISO M3 x 5mm  
2 & 3 pole circuit breakers required for 120/240 VAC (Maximum application rating  
code C) applications, have all poles identical except when specifying auxiliary /  
alarmꢀswitchꢀwhichꢀisꢀnormallyꢀsuppliedꢀinꢀextremeꢀrightꢀpoleꢀperꢀfigureꢀB.ꢀTerminalꢀꢀ  
barriers are required on all multipole breakers.  
1
2
yes  
yes  
Third pole is for 120/240 VAC applications requiring neutral disconnect. The 3rd  
pole has the same construction as poles 1 & 2.  
11 MAXIMUM APPLICATION RATING  
3
On multi-pole breakers, one auxiliary. switch is supplied, mounted in the extreme  
right pole.  
A
B
C
D
K
F
65 DC  
125 DC  
120/240 AC  
240 AC  
120 AC  
277 AC  
80 DC  
VDE approval on auxiliary switch codes 2, 3 & 4 only.  
2
Auxiliary / Alarm Switch with Independent Circuit ie: separate from breaker circuit,  
only available with circuit breakers rated 50 amp maximum at 80 VDC, 125 VDC,  
and 120 VAC. Auxiliary / Alarm Switch with Dependent Circuit ie: same as circuit  
breaker, is supplied from factory with common terminal of auxiliary / alarm switch  
connected to line terminal on 120/240 and 240 VAC ratings. Circuit breakers rated  
120 VAC 50 amp maximum can be supplied with Auxiliary/Alarm switch common  
terminal connected to breaker line terminal. Consult factory for special catalog  
number.  
M
12 AGENCY APPROVAL11  
4
5
Available up to 50 amps maximum.  
A
w/o approvals  
UL489ꢀListed,ꢀCSAꢀCertifiedꢀ&ꢀVDEꢀCertified  
ꢀUL489ꢀListedꢀ&ꢀCSAꢀCertified  
Current ratings 71 - 100 with VDE approvals are available up to two poles  
maximum.  
Fꢀꢀ  
Gꢀ  
Jꢀꢀ  
6
7
8
9
Terminal Codes 9 & C are not VDE approved.  
Terminal Code 1 available to 60 amps maximum.  
UL489ꢀListed,ꢀCSAꢀCertifiedꢀ&ꢀTUVꢀCertified  
Terminal Codes 2, 4, 5 & C available to 50 amps maximum.  
Terminal Codes 3, 6 & 9 available to 100 amps maximum.  
10 Terminal Code A available to 100 amps maximum.  
11 VDE and TUV approvals require Dual (I-O, ON-OFF) markings on all handles.  
12 Barriers supplied on multi-pole units only.  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
C-Series Sealed Toggle UL Recognized – Ordering Scheme  
11  
C M 3 B 0 10 450 1 0 1 C  
8
9
10  
11  
Agency  
Approval  
1
2
3
4
5
6
7
Terminal  
Legend  
Plate  
Mounting  
Bezel/Barrier  
Series  
Actuator  
Poles  
Circuit  
Aux/Alarm  
Switch  
Frequency  
& Delay  
Current Rating  
7 CURRENT RATING (AMPERES)9  
1 SERIES  
C
CODE  
AMPERES  
020  
025  
030  
035  
040  
045  
050  
055  
060  
065  
070  
075  
080  
085  
090  
095  
210  
215  
220  
225  
230  
0.020  
0.025  
0.030  
0.035  
0.040  
0.045  
0.050  
0.055  
0.060  
0.065  
0.070  
0.075  
0.080  
0.085  
0.090  
0.095  
0.100  
0.150  
0.200  
0.250  
0.300  
235  
240  
245  
250  
255  
260  
265  
270  
275  
280  
285  
290  
295  
410  
512  
415  
517  
420  
522  
425  
527  
0.350  
0.400  
0.450  
0.500  
0.550  
0.600  
0.650  
0.700  
0.750  
0.800  
0.850  
0.900  
0.950  
1.000  
1.250  
1.500  
1.750  
2.000  
2.250  
2.500  
2.750  
430  
435  
440  
445  
450  
455  
460  
465  
470  
475  
480  
485  
490  
495  
610  
710  
611  
711  
612  
712  
613  
3.000  
3.500  
4.000  
4.500  
5.000  
5.500  
6.000  
6.500  
7.000  
7.500  
8.000  
8.500  
9.000  
9.500  
10.000  
10.500  
11.000  
11.500  
12.000  
12.500  
13.000  
614  
14.000  
15.000  
16.000  
17.000  
18.000  
20.000  
22.000  
24.000  
25.000  
30.000  
35.000  
40.000  
50.000  
60.000  
70.000  
80.000  
85.000  
90.000  
95.000  
100.000  
615  
616  
617  
618  
620  
622  
624  
625  
630  
635  
640  
650  
660  
670  
680  
685  
690  
695  
810  
2 ACTUATOR1  
M
Sealed Toggle, one per pole  
3 POLES  
1
One  
2
Two  
3
Three  
4 CIRCUIT  
F3  
Relay Trip (current)  
Relay Trip (voltage)  
Dual Coil with Shunt Trip  
Voltage Coil  
Dual Coil with Relay Trip  
Voltage Coil  
2
3
A
B
C
D
Switch Only (no coil)  
G
H
3,4  
Series Trip (current)  
Series Trip (voltage)  
Shunt Trip (current)  
Shunt Trip (voltage)  
9
9
9
9
9
9
9
3
3
3,4  
K
E
5 AUXILIARY/ALARM SWITCH  
0
2
3
4
without Aux Switch  
S.P.D.T., 0.110 Q.C. Term.  
S.P.D.T., 0.139 Solder Lug  
S.P.D.T., 0.110 Q.C. Term.  
(Gold Contacts)  
6
8
9
S.P.S.T., 0.139 Solder Lug  
S.P.S.T., 0.187 Q.C. Term.  
S.P.D.T., 0.187 Q.C. Term.  
VOLTAGE COIL (NOMINAL RATED VOLTAGE)7  
CODE  
RATING  
A06 6DC  
A12 12DC  
A18 18DC  
A24 24DC  
A32 32DC  
A48 48DC  
A65 65DC  
J12 12AC  
J18 18AC  
J24 24AC  
J48 48AC  
J65 65AC  
K20 120AC  
L40 240AC  
6 FREQUENCY & DELAY  
J06  
6AC  
032  
106  
11  
12  
14  
16  
206  
21  
22  
24  
26  
DC 50/60Hz, Switch Only  
DC Instantaneous  
DC Ultra Short  
DC Short  
DC Medium  
DC Long  
50/60Hz Instantaneous  
50/60Hz Ultra Short  
50/60Hz Short  
50/60Hz Medium  
50/60Hz Long  
30  
31  
32  
34  
36  
42  
44  
46  
52  
54  
56  
DC 50/60Hz Instantaneous  
DC 50/60Hz Ultra Short  
DC 50/60Hz Short  
DC 50/60Hz Medium  
DC 50/60Hz Long  
50/60Hz Short, Hi-Inrush  
50/60Hz Medium, Hi-Inrush  
50/60Hz Long, Hi-Inrush  
DC Short, Hi-Inrush  
DC Medium, Hi-Inrush  
DC Long, Hi-Inrush  
8 TERMINAL  
19  
Stud 10-32  
Screw 10-32  
Stud 1/4-20  
Stud M5 x 0.8  
Screw M5 x 0.8  
611  
712  
911  
A13  
C10  
Stud M6  
210  
311  
410  
510  
0.250 Double Click Connect  
7/16” Clip Terminal  
Plug-In Stud  
7
7
7
7
5/16” Clip Terminal  
7
9 LEGENDPLATE  
0
No Legend  
Notes:  
1
Actuator Code M: Handle location as viewed from front of breaker:  
2 pole - right pole 3 pole - center pole  
10 MOUNTING/BARRIERS  
MOUNTING STYLE  
1
2
Switch Only circuits, rated up to 50 amps and 3 poles, and only available with VDE.  
For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current  
Code 650. For 55-70 amps, select Current Code 670. For 75-100 amps, select  
Current Code 810.  
Circuit Codes D,E,F,G,H & K available with Terminal Codes 1,2,4 & 5 only.  
Consult factory for available Dual Coil options, as special catalog number is  
required. Dual Coil Voltage Coils with Shunt Trip Construction trip instantaneously  
on line voltage. Dual Coil Voltage Coils require 30VA minimum power to trip  
instantaneously and are rated for intermittent duty only.  
BARRIERS  
no  
Standard Hex Nut (multi-pole units only) yes  
Standard Hex Nut  
A
3
4
11 AGENCY APPROVAL  
C
L
T
UL Recognized & CSA Accepted  
UL Recognized & CSA Accepted with listed construction  
UL Recognized & CSA Accepted, UL1500 ignition protection  
5
Auxiliary Switch available with Series Trip and Switch Only circuits. On multi-pole  
breakers, one aux. switch is supplied, mounted in the extreme right pole.  
Voltage coils not rated for continuous duty. Available only with delay codes 10 & 20.  
Available with Circuit Codes B & D only, and up to 50 amps maximum.  
Consult factory for current ratings 71-100, in three pole units, available as special  
catalog number only.  
6
7
8
9
Terminal Code 1 available to 60 amps maximum.  
10 Terminal Codes 2, 4, 5 and C available to 50 amps maximum.  
11 Terminal Codes 3, 6 & 9 available to 100 amps maximum.  
12 Terminal Code 7 available to 25 amps maximum.  
13 Terminal Code A available to 100 amps maximum.  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
12  
C-Series Rocker UL Recognized – Ordering Scheme  
14 450  
C C 3 B 0  
1 2 1 D  
6
7
8
9
10  
Mounting/  
Barriers  
11  
Agency  
Approval  
1
2
3
4
5
Frequency  
& Delay  
Current Rating  
Terminal  
Actuator  
Color  
Series  
Actuator  
Poles  
Circuit  
Aux/Alarm  
Switch  
1 SERIES  
C
7 CURRENT RATING (AMPERES)  
CODE AMPERES  
020 0.020  
025 0.025  
030 0.030  
035 0.035  
040 0.040  
045 0.045  
050 0.050  
055 0.055  
060 0.060  
065 0.065  
070 0.070  
075 0.075  
080 0.080  
085 0.085  
090 0.090  
095 0.095  
210 0.100  
215 0.150  
220 0.200  
225 0.250  
230 0.300  
235 0.350  
240 0.400  
245 0.450  
250 0.500  
255 0.550  
260 0.600  
265 0.650  
270 0.700  
275 0.750  
280 0.800  
285 0.850  
290 0.900  
295 0.950  
410 1.000  
512 1.250  
415 1.500  
517 1.750  
420 2.000  
522 2.250  
425 2.500  
527 2.750  
430 3.000  
614 14.000  
615 15.000  
616 16.000  
617 17.000  
618 18.000  
620 20.000  
622 22.000  
624 24.000  
625 25.000  
630 30.000  
635 35.000  
640 40.000  
650 50.000  
435 3.500  
440 4.000  
445 4.500  
450 5.000  
455 5.500  
460 6.000  
465 6.500  
470 7.000  
475 7.500  
480 8.000  
485 8.500  
490 9.000  
495 9.500  
610 10.000  
710 10.500  
2 ACTUATOR1  
Single color  
Two Color Visi-Rocker  
J
Vertical legend  
C
D
E
F
G
H
Indicate ON, vertical legend  
Indicate ON, horizontal legend  
Indicate ON, no legend  
Indicate OFF, vertical legend  
Indicate OFF, horizontal legend  
Indicate OFF, no legend  
K
L
Horizontal legend  
No legend  
Push-To-Reset, Single color  
R
U
V
Vertical legend  
Horizontal legend  
No legend  
Push-To-Reset, Visi-Rocker  
N
O
P
Indicate OFF,  
vertical legend  
Indicate OFF,  
horizontal legend  
Indicate OFF,  
no legend  
9
660 60.000  
9
670 70.000  
9
680 80.000  
9
611  
711  
11.000  
11.500  
685 85.000  
9
690 90.000  
9
612 12.000  
712 12.500  
613 13.000  
695 95.000  
9
810 100.000  
VOLTAGE COIL (NOMINAL RATED VOLTAGE)7  
CODE  
RATING  
A06 6DC  
A12 12DC  
A18 18DC  
A24 24DC  
A32 32DC  
A48 48DC  
A65 65DC  
J06 6AC  
J12 12AC  
J18 18AC  
J24 24AC  
J48 48AC  
J65 65AC  
K20 120AC  
L40 240AC  
3 POLES2  
1
One  
2
Two  
3
Three  
4 CIRCUIT  
F4  
Relay Trip (Current)  
Relay Trip (Voltage)  
Dual Coil with Shunt Trip  
Voltage Coil  
Dual Coil with Relay Trip  
Voltage Coil  
A3  
B
Switch Only (No Coil)  
G4  
H4,5  
8 TERMINAL  
10  
12  
13  
Series Trip (Current)  
Series Trip (Voltage)  
Shunt Trip (Current)  
Shunt Trip (Voltage)  
1
2
3
4
5
Stud 10-32  
6
7
9
Stud M6  
11  
12  
11  
11  
C
Screw 10-32  
Stud 1/4-20  
Stud M5 x 0.8  
Screw M5 x 0.8  
0.250 Double Quick Connect  
7/16” Clip Terminal  
Plug-In Stud  
D4  
E4  
K4,5  
14  
A
C
5/16” Clip Terminal  
5 AUXILIARY/ALARM SWITCH6  
0
2
3
4
without Aux Switch  
9 ACTUATOR COLOR & LEGEND16,17,18  
S.P.D.T., 0.110 Q.C. Term.  
S.P.D.T., 0.139 Solder Lug  
S.P.D.T., 0.110 Q.C. Term.  
(Gold Contacts)  
6
8
9
S.P.S.T., 0.139 Solder Lug  
S.P.S.T., 0.187 Q.C. Term.  
S.P.D.T., 0.187 Q.C. Term.  
Actuator or  
Visi-Color  
Marking:  
Marking Color:  
Single Color  
Rocker/Handle  
Black  
Color:  
White  
Black  
Red  
I-O  
A
C
F
ON-OFF  
Dual/None  
Visi-Rocker  
White  
n/a  
B
D
G
J
1
2
3
4
5
6
7
8
White  
6 FREQUENCY & DELAY  
White  
Red  
03  
107  
11  
DC 50/60Hz, Switch Only  
DC Instantaneous  
DC Ultra Short  
DC Short  
DC Medium  
DC Long  
50/60Hz Instantaneous  
50/60Hz Ultra Short  
50/60Hz Short  
50/60Hz Medium  
50/60Hz Long  
30  
DC 50/60Hz Instantaneous  
DC 50/60Hz Ultra Short  
DC 50/60Hz Short  
DC 50/60Hz Medium  
DC 50/60Hz Long  
50/60Hz Short, Hi-Inrush  
50/60Hz Medium, Hi-Inrush  
50/60Hz Long, Hi-Inrush  
DC Short, Hi-Inrush  
DC Medium, Hi-Inrush  
DC Long, Hi-Inrush  
Green  
Blue  
H
K
M
P
White  
Green  
Blue  
31  
L
White  
32  
Yellow  
Gray  
Orange  
N
Q
S
Black  
Yellow  
Gray  
12  
14  
16  
207  
21  
22  
24  
26  
34  
Black  
36  
R
Black  
Orange  
428  
448  
468  
528  
548  
568  
10 MOUNTING/BARRIERS1  
STANDARD ROCKER BEZEL  
BARRIERS  
no  
VOLTAGE  
<300  
1
2
3
4
5
6
6-32 x 0.195 inches  
6-32 x 0.195 inches  
ꢀꢀ 6-32ꢀxꢀ0.195ꢀinchesꢀ  
ISO M3 x 5mm  
yes  
<300  
19  
19  
yesꢀ  
no  
≥300  
Notes:  
<300  
1
2
Push-To-Reset actuators have OFF portion of rocker shrouded.  
ISO M3 x 5mm  
yes  
<300  
Multi-pole breakers have all poles identical except when specifying Aux. switch and/  
or mixed poles, and have one rocker per breaker. Rocker location as viewed from  
front panel: 2 pole – left pole; 3 pole – center pole.  
ꢀꢀ ISOꢀM3ꢀxꢀ5mmꢀ  
ROCKERGUARD BEZEL  
6-32 x 0.195 inches  
6-32 x 0.195 inches  
yesꢀ  
≥300  
3
Switch Only circuits, rated up to 50 amps and 3 poles, and only available with VDE  
Certificationꢀwhenꢀtiedꢀtoꢀaꢀprotectedꢀpoleꢀ(CircuitꢀCodeꢀB,ꢀC,ꢀDꢀorꢀH.),ꢀForꢀ.02ꢀtoꢀꢀ  
30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650.  
For 55-70 amps, select Current Code 670. For 75-100 amps, select Current Code 810.  
Circuit Codes D,E,F,G,H & K available with Terminal Codes 1,2,4 & 5 only. Circuit  
Codes D,F,H & K available up to 50 amps maximum Current Rating.  
Consult factory for available Dual Coil options, as special catalog number is  
required. Dual Coil Voltage Coils with Shunt Trip Construction trip instantaneously  
on line voltage. Dual Coil Voltage Coils require 30VA minimum power to trip  
instantaneously and are rated for intermittent duty only.  
A
C
E
G
J
no  
<300  
<300  
≥300  
<300  
<300  
≥300  
yes  
yesꢀ  
no  
19  
ꢀꢀ 6-32ꢀxꢀ0.195ꢀinchesꢀ  
ISO M3 x 5mm  
4
5
ISO M3 x 5mm  
yes  
yesꢀ  
19  
L
ꢀꢀ ISOꢀM3ꢀxꢀ5mmꢀ  
PUSH-TO-RESET BEZEL  
6-32 x 0.195 inches  
6-32 x 0.195 inches  
ꢀꢀ 6-32ꢀxꢀ0.195ꢀinchesꢀ  
ISO M3 x 5mm  
B
D
no  
<300  
<300  
≥300  
<300  
<300  
≥300  
yes  
yesꢀ  
no  
19  
F
6
Auxiliary Switch available with Series Trip and Switch Only circuits. On multi-pole  
breakers, one aux. switch is supplied, mounted in the extreme right pole. Auxiliary  
switch codes 2, 3 & 4 are VDE approved.  
H
J
ISO M3 x 5mm  
ꢀꢀ ISOꢀM3ꢀxꢀ5mmꢀ  
yes  
yesꢀ  
19  
7
8
9
Voltage coils not rated for continuous duty. Available only with delay codes 10 & 20.  
Available with Circuit Codes B & D only, and up to 50 amps maximum.  
Current Ratings 60-70 are available up to four poles maximum. Ratings 71-100 are  
available up to two poles maximum.  
M
10 Terminal Code 1 available to 60 amps maximum.  
11 AGENCY APPROVAL  
11 Terminal Codes 2,4,5 & C available to 50 amps maximum.  
12 Terminal Codes 3,6 & 9 available to 100 amps maximum.  
13 Terminal Code 7 available to 25 amps maximum.  
C
UL Recognized & CSA Accepted  
VDEꢀCertified,ꢀULꢀRecognizedꢀ&ꢀCSAꢀAccepted  
TUVꢀCertified,ꢀULꢀRecognizedꢀ&ꢀCSAꢀAccepted  
UL489ꢀConstruction:ꢀVDEꢀCertified,ꢀULꢀRecognizedꢀ&ꢀCSAꢀAccepted  
UL Rec. STD 1077, UL Rec. 1500 (ignition protected), & CSA Accepted  
UL489 Construction: UL Recognized & CSA Accepted  
Dꢀꢀ  
Eꢀꢀ  
Hꢀꢀ  
I
14 Terminal Code A available to 100 amps maximum.  
15 Terminal Codes 7, 9 & C are not VDE approved.  
16 Color shown is visi and legend with remainder of rocker black  
17 Legend on Push-to-reset bezel/shroud is white when single color rocker is ordered.  
Dual = ON-OFF/I-O legend with actuator codes C - G, and J, K, N, O, R, & U. None  
= no legend with actuator codes H, L, P, V. Rockerguard available with actuator  
codes C - L. Push-to-reset available with actuator codes N, O, P, R, U, V.  
18 VDE/TUV approval requires Dual (I-O, ON-OFF) or I-O markings on rocker.  
19 VDE/TUV: 30 amps max.; UL/CSA: 50 amps max.; Available in 2 - 4 poles only  
and limited to AC Delays. “General Purpose amps” not rated for “full load amps” or  
to be used in applications with a motor.  
L
Rꢀ  
UL489ꢀConstruction:ꢀTUVꢀCertified,ꢀULꢀRecognizedꢀ&ꢀCSAꢀAccepted  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
C-Series Rocker UL Listed – Ordering Scheme  
13  
C C 3 B 0 14 450 1 2 A K G  
8
9
10  
Mounting/  
Barriers  
11  
12  
1
2
3
4
5
6
7
Terminal  
Actuator  
Color  
Max. App. Agency  
Rating  
Series  
Actuator  
Poles  
Circuit  
Aux/Alarm  
Switch  
Frequency  
& Delay  
Current Rating  
Approval  
7 CURRENT RATING (AMPERES)4  
1 SERIES  
C
CODE AMPERES  
210 0.100  
215 0.150  
220 0.200  
225 0.250  
230 0.300  
235 0.350  
240 0.400  
245 0.450  
250 0.500  
255 0.550  
260 0.600  
265 0.650  
270 0.700  
275 0.750  
280 0.800  
285 0.850  
290 0.900  
295 0.950  
410 1.000  
512 1.250  
415 1.500  
517 1.750  
420 2.000  
522 2.250  
425 2.500  
527 2.750  
430 3.000  
435 3.500  
440 4.000  
445 4.500  
450 5.000  
455 5.500  
460 6.000  
465 6.500  
470 7.000  
475 7.500  
480 8.000  
485 8.500  
490 9.000  
495 9.500  
610 10.000  
710 10.500  
611 11.000  
711 11.500  
612 12.000  
712 12.500  
613 13.000  
614 14.000  
615 15.000  
616 16.000  
617 17.000  
618 18.000  
620 20.000  
622 22.000  
624 24.000  
625 25.000  
630 30.000  
635 35.000  
640 40.000  
650 50.000  
660 60.000  
670 70.000  
680 80.000  
685 85.000  
690 90.000  
695 95.000  
810 100.000  
2 ACTUATOR1  
Two Color Visi-Rocker  
C
D
F
Indicate ON, vertical legend  
Single color  
Indicate ON, horizontal legend  
Indicate OFF, vertical legend  
Indicate OFF, horizontal legend  
J
K
Vertical legend  
Horizontal legend  
G
ROCKER STYLE DESCRIPTIONS  
INDICATE "ON"  
INDICATE "OFF"  
SINGLE COLOR  
CODE "C"  
CODE "F"  
CODE "J"  
CODE "K"  
LINE  
INDICATE  
COLOR  
LINE  
LINE  
LOCATION  
CODE "D"  
CODE "G"  
LINE  
LINE  
LINE  
8 TERMINAL  
5
7
1
2
Stud 10-32  
6
9
Stud M6  
7/16” Clip Terminal  
Plug-In Stud  
6
7,8  
7,8  
Screw 10-32 w/saddle &  
3 POLES1  
washer clamps  
Stud 1/4-20  
Stud M5 x 0.8  
Screw M5 x 0.8 w/saddle &  
washer clamps  
A
C
7
6
6
6,8  
1
One  
2
Two  
3
Three  
3
4
5
5/16” Clip Terminal  
4 CIRCUIT  
B
Series Trip (current)  
9 ACTUATOR COLOR & LEGEND11  
5 AUXILIARY/ALARM SWITCH2  
Actuator or  
0
2
3
4
without Aux Switch  
Visi-Color  
Marking:  
Marking Color:  
S.P.D.T., 0.110 Q.C. Term.  
S.P.D.T., 0.139 Solder Lug  
S.P.D.T., 0.110 Q.C. Term.  
(Gold Contacts)  
6
8
9
S.P.S.T., 0.139 Solder Lug  
S.P.S.T., 0.187 Q.C. Term.  
S.P.D.T., 0.187 Q.C. Term.  
Single Color  
10  
Color:  
White  
Black  
Red  
ON-OFF  
Dual  
Rocker/Handle  
Visi-Rocker  
White  
n/a  
B
D
G
J
1
2
3
4
5
6
7
8
Black  
White  
White  
Red  
Green  
Blue  
White  
Green  
Blue  
L
White  
6 FREQUENCY & DELAY  
26  
42  
44  
46  
52  
54  
56  
50/60Hz Long  
8
8
8
8
8
Yellow  
Gray  
Orange  
N
Q
S
Black  
Yellow  
Gray  
11  
12  
14  
16  
21  
22  
24  
DC Ultra Short  
DC Short  
DC Medium  
50/60Hz Short, Hi-Inrush  
50/60Hz Medium, Hi-Inrush  
50/60Hz Long, Hi-Inrush  
DC Short, Hi-Inrush  
DC Medium, Hi-Inrush  
DC Long, Hi-Inrush  
Black  
Black  
Orange  
DC Long  
50/60Hz Ultra Short  
50/60Hz Short  
50/60Hz Medium  
10 MOUNTING/BARRIERS12  
13  
Standard Rocker Bezel  
Threaded Insert, 2 per pole  
6-32 X 0.195 inches  
BARRIERS  
A
C
yes  
yes  
Notes:  
ISO M3 x 5mm  
1
Multi-pole breakers have all breakers identical except when specifying Aux. switch  
and/or mixed poles, and have one rocker per breaker.  
On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right  
pole.  
Available up to 50 amps maximum.  
Current ratings 71 - 100 with VDE approvals are available up to two poles maximum.  
Terminal Code 1 available to 60 amps maximum.  
Rockerguard Bezel  
Threaded Insert, 2 per pole  
6-32 x 0.195 inches  
2
B
D
yes  
yes  
ISO M3 x 5mm  
3
4
5
6
7
8
9
Terminal Codes 2, 4, 5 & C available to 50 amps maximum.  
Terminal Codes 3, 6, 9 & A available to 100 amps maximum.  
Terminal Codes 9 & C are not VDE approved.  
11 MAXIMUM APPLICATION RATING  
A
B
C
D
F
K
M
65 DC  
125 DC  
120/240 AC  
240 AC  
277 AC  
120 AC  
80 DC  
Color shown is visi and legend with remainder of rocker black  
14  
10 Dual = ON-OFF/I-O legend on actuator.  
11 VDE and TUV approval requires Dual (I-O, ON-OFF) markings on rocker.  
12 Rockerguard available with all actuator codes.  
13 Barriers supplied on multi-pole units only.  
14 2 & 3 pole circuit breakers required for 120/240 AC rating.  
12 AGENCY APPROVAL  
A
Fꢀꢀ  
G
without approvals  
ULꢀ489ꢀListed,ꢀCSAꢀCertified,ꢀ&ꢀVDEꢀCertified  
ULꢀ489ꢀListedꢀ&ꢀCSAꢀCertified  
Jꢀꢀ  
UL489ꢀListed,ꢀCSAꢀCertifiedꢀ&ꢀTUVꢀCertified  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
14  
C-Series Flat Rocker UL Recognized – Ordering Scheme  
C 1 2 B 0 10 450 1 2 1 E  
8
9
10  
Mounting/  
Barriers  
11  
Agency  
Approval  
1
2
3
4
5
6
7
Terminal  
Actuator  
Color  
Series  
Actuator  
Poles  
Circuit  
Aux/Alarm  
Switch  
Frequency  
& Delay  
Current Rating  
1 SERIES  
C
7 CURRENT RATING (AMPERES)9  
CODE AMPERES  
020 0.020  
025 0.025  
030 0.030  
035 0.035  
040 0.040  
045 0.045  
050 0.050  
055 0.055  
060 0.060  
065 0.065  
070 0.070  
075 0.075  
080 0.080  
085 0.085  
090 0.090  
095 0.095  
210 0.100  
215 0.150  
220 0.200  
225 0.250  
230 0.300  
235 0.350  
240 0.400  
245 0.450  
250 0.500  
255 0.550  
260 0.600  
265 0.650  
270 0.700  
275 0.750  
280 0.800  
285 0.850  
290 0.900  
295 0.950  
410 1.000  
512 1.250  
415 1.500  
517 1.750  
420 2.000  
522 2.250  
425 2.500  
527 2.750  
430 3.000  
435 3.500  
440 4.000  
445 4.500  
450 5.000  
455 5.500  
460 6.000  
465 6.500  
470 7.000  
475 7.500  
480 8.000  
485 8.500  
490 9.000  
495 9.500  
610 10.000  
710 10.500  
614 14.000  
615 15.000  
616 16.000  
617 17.000  
618 18.000  
620 20.000  
622 22.000  
624 24.000  
625 25.000  
630 30.000  
635 35.000  
640 40.000  
650 50.000  
2 ACTUATOR1  
Two Color Visi-Rocker  
1
2
Indicate OFF, vertical legend  
Indicate OFF, horizontal legend  
Single color  
3
4
Vertical legend  
Horizontal legend  
Push-To-Reset, Visi-Rocker  
5
6
Indicate OFF, vertical legend  
Indicate OFF, horizontal legend  
9
660 60.000  
Push-To-Reset , Single color  
9
670 70.000  
7
8
Vertical legend  
Horizontal legend  
9
680 80.000  
9
611  
711  
11.000  
11.500  
685 85.000  
9
690 90.000  
9
612 12.000  
712 12.500  
613 13.000  
695 95.000  
9
3 POLES2  
810 100.000  
1
One  
2
Two  
3
Three  
VOLTAGE COIL (NOMINAL RATED VOLTAGE)7  
CODE  
RATING  
4
A06 6DC  
A12 12DC  
A18 18DC  
A24 24DC  
A32 32DC  
A48 48DC  
A65 65DC  
J12 12AC  
J18 18AC  
J24 24AC  
J48 48AC  
J65 65AC  
K20 120AC  
L40 240AC  
4 CIRCUIT  
F
Relay Trip (Current)  
Relay Trip (Voltage)  
Dual Coil with Shunt Trip  
Voltage Coil  
Dual Coil with Relay Trip  
Voltage Coil  
3
4
4,5  
A
B
C
D
Switch Only (No Coil)  
G
H
Series Trip (Current)  
Series Trip (Voltage)  
Shunt Trip (Current)  
Shunt Trip (Voltage)  
J06  
6AC  
4
4
4,5  
K
E
8 TERMINAL  
10  
12  
1
2
3
4
5
Stud 10-32  
6
7
9
Stud M6  
11  
12  
11  
11  
13  
15  
14  
Screw 10-32  
Stud 1/4-20  
0.250 Double Quick Connect  
7/16” Clip Terminal  
Plug-In Stud  
5 AUXILIARY/ALARM SWITCH6  
0
2
3
4
without Aux Switch  
Stud M5 x 0.8  
Screw M5 x 0.8  
A
C
15  
S.P.D.T., 0.110 Q.C. Term.  
S.P.D.T., 0.139 Solder Lug  
S.P.D.T., 0.110 Q.C. Term.  
(Gold Contacts)  
6
8
9
S.P.S.T., 0.139 Solder Lug  
S.P.S.T., 0.187 Q.C. Term.  
S.P.D.T., 0.187 Q.C. Term.  
5/16” Clip Terminal  
9 ACTUATOR COLOR & LEGEND16,17,18  
Actuator or  
Visi-Color  
Marking:  
Marking Color:  
6 FREQUENCY & DELAY  
30  
31  
32  
34  
36  
42  
44  
46  
52  
54  
56  
DC 50/60Hz Instantaneous  
DC 50/60Hz Ultra Short  
DC 50/60Hz Short  
DC 50/60Hz Medium  
DC 50/60Hz Long  
50/60Hz Short, Hi-Inrush  
50/60Hz Medium, Hi-Inrush  
50/60Hz Long, Hi-Inrush  
DC Short, Hi-Inrush  
DC Medium, Hi-Inrush  
DC Long, Hi-Inrush  
03  
10  
11  
12  
14  
16  
20  
21  
22  
24  
26  
DC 50/60Hz, Switch Only  
DC Instantaneous  
DC Ultra Short  
DC Short  
DC Medium  
DC Long  
50/60Hz Instantaneous  
50/60Hz Ultra Short  
50/60Hz Short  
50/60Hz Medium  
50/60Hz Long  
Single Color  
Rocker/Handle  
Black  
7
Color:  
White  
Black  
Red  
I-O  
A
C
F
H
K
M
P
ON-OFF  
Dual/None  
Visi-Rocker  
White  
n/a  
B
D
G
J
1
2
3
4
5
6
7
8
White  
8
8
8
8
8
8
White  
Red  
Green  
Blue  
White  
Green  
Blue  
L
White  
7
Yellow  
Gray  
N
Q
S
Black  
Yellow  
Gray  
Black  
Orange  
R
Black  
Orange  
Notes:  
10 MOUNTING/BARRIERS1  
STANDARD ROCKER BEZEL  
1
2
Push-to-reset actuators have OFF portion of rocker shrouded.  
BARRIERS  
no  
VOLTAGE  
<300  
Multi-pole breakers have all poles identical except when specifying Aux. switch and/or  
mixed poles, and have one rocker per breaker. Rocker location as viewed from front  
panel: 2 pole – left pole; 3 pole – center pole.  
1
2
3
4
5
6
6-32 x 0.195 inches  
6-32 x 0.195 inches  
ꢀꢀ 6-32ꢀxꢀ0.195ꢀinchesꢀꢀ  
ISO M3 x 5mm  
yes  
<300  
19  
yesꢀꢀ  
no  
≥300  
3
Switch Only circuits, rated up to 50 amps and 3 poles, and only available with VDE  
Certificationꢀwhenꢀtiedꢀtoꢀaꢀprotectedꢀpoleꢀ(CircuitꢀCodeꢀB,ꢀC,ꢀDꢀorꢀH.).ꢀForꢀ.02ꢀtoꢀ30ꢀꢀ  
amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. For  
55-70 amps, select Current Code 670. For 75-100 amps, select Current Code 810.  
Circuit Codes D,E,F,G,H & K available with Terminal Codes 1,2,4 & 5 only. Circuit  
Codes D,F,H & K available up to 50 amps maximum Current Rating.  
Consult factory for available Dual Coil options, as special catalog number is required.  
Dual Coil Voltage Coils with Shunt Trip Construction trip instantaneously on line  
voltage. Dual Coil Voltage Coils require 30VA minimum power to trip instantaneously  
and are rated for intermittent duty only.  
<300  
ISO M3 x 5mm  
yes  
<300  
19  
ꢀꢀ ISOꢀM3ꢀxꢀ5mmꢀꢀ  
RECESSED OFF ROCKER  
yesꢀꢀ  
≥300  
4
5
7
8
6-32 x 0.195 inches  
6-32 x 0.195 inches  
6-32ꢀxꢀ0.195ꢀinchesꢀꢀ  
ISO M3 x 5mm  
ISO M3 x 5mm  
ISOꢀM3ꢀxꢀ5mmꢀꢀ  
no  
<300  
<300  
≥300  
<300  
<300  
≥300  
yes  
yesꢀꢀ  
no  
9ꢀꢀ  
A
C
yes  
yesꢀꢀ  
6
Auxiliary Switch available with Series Trip and Switch Only circuits. On multi-pole  
breakers, one aux. switch is supplied, mounted in the extreme right pole. Auxilary  
switch codes 2, 3 & 4 are VDE approved.  
Eꢀꢀ  
PUSH-TO-RESET BEZEL  
B
D
6-32 x 0.195 inches  
6-32 x 0.195 inches  
ꢀꢀ 6-32ꢀxꢀ0.195ꢀinchesꢀꢀ  
ISO M3 x 5mm  
no  
<300  
<300  
≥300  
<300  
<300  
≥300  
7
8
9
Voltage coils not rated for continuous duty. Available only with delay codes 10 and 20.  
Available with Circuit Codes B & D only, and up to 50 amps maximum.  
Current ratings 60-70 are available up to four poles maximum. Current ratings 71 -  
100 are available up to two poles maximum.  
yes  
yesꢀꢀ  
no  
19  
F
H
J
ISO M3 x 5mm  
yes  
yesꢀꢀ  
10 Terminal Code 1 available to 60 amps maximum.  
19  
M
ꢀꢀ ISOꢀM3ꢀxꢀ5mmꢀꢀ  
11 Terminal Codes 2,4,5 & C available to 50 amps maximum.  
12 Terminal Codes 3,6 & 9 available to 100 amps maximum.  
13 Terminal Code 7 available to 25 amps maximum.  
14 Terminal Code A available to 100 amps maximum.  
15 Terminal Codes 7, 9 & C are not VDE approved.  
11 AGENCY APPROVAL  
C
Eꢀꢀ  
I
UL Recognized & CSA Accepted  
TUVꢀCertified,ꢀULꢀRecognizedꢀ&ꢀCSAꢀAccepted  
UL Rec. STD 1077, UL Rec. 1500 (ignition protected), & CSA Accepted  
UL489 Construction: UL Recognized & CSA Accepted  
16 Color shown is visi & legend with remainder of rocker black. Dual = ON-OFF/I-O  
legend.  
17 Legend on Push-to-reset bezel/shroud is white with single color actuator codes 7 &  
8. Legend on Push-to-reset bezel/shroud matches visi-color of rocker with actuator  
codes 5 & 6.  
L
Rꢀꢀ  
UL489ꢀConstruction:ꢀTUVꢀCertified,ꢀULꢀRecognizedꢀ&ꢀCSAꢀAccepted  
18 VDE/TUV approval requires Dual (I-O, ON-OFF) or I-O markings on rocker.  
19 VDE/TUV: 30 amps max.; UL/CSA: 50 amps max.; Available in 2 & 3 poles only and  
limited to AC Delays. “General Purpose amps” not rated for “full load amps” or to be  
used in applications with a motor.  
20 Recessed “OFF SIDE” available with actuator codes 1,2,3&4. Legends on rocker are  
available in ink stamping only.  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
C-Series Flat Rocker UL Listed – Ordering Scheme  
15  
C 1 2 B 0 14 450 1 2 A K G  
8
9
10  
Mounting/  
Barriers  
11  
12  
1
2
3
4
5
6
7
Terminal  
Actuator  
Color  
Max. App. Agency  
Rating  
Series  
Actuator  
Poles  
Circuit  
Aux/Alarm  
Switch  
Frequency  
& Delay  
Current Rating  
Approval  
7 CURRENT RATING (AMPERES)5  
1 SERIES  
C
CODE AMPERES  
210 0.100  
215 0.150  
220 0.200  
225 0.250  
230 0.300  
235 0.350  
240 0.400  
245 0.450  
250 0.500  
255 0.550  
260 0.600  
265 0.650  
270 0.700  
275 0.750  
280 0.800  
285 0.850  
290 0.900  
295 0.950  
410 1.000  
512 1.250  
415 1.500  
517 1.750  
420 2.000  
522 2.250  
425 2.500  
527 2.750  
430 3.000  
435 3.500  
440 4.000  
445 4.500  
450 5.000  
455 5.500  
460 6.000  
465 6.500  
470 7.000  
475 7.500  
480 8.000  
485 8.500  
490 9.000  
495 9.500  
610 10.000  
710 10.500  
618 18.000  
620 20.000  
622 22.000  
624 24.000  
625 25.000  
630 30.000  
635 35.000  
640 40.000  
650 50.000  
660 60.000  
670 70.000  
680 80.000  
685 85.000  
690 90.000  
695 95.000  
810 100.000  
2 ACTUATOR1  
Two Color Visi-Rocker  
1
2
Indicate OFF, vertical legend  
Indicate OFF, horizontal legend  
Single color  
3
4
Vertical legend  
Horizontal legend  
611  
711  
11.000  
11.500  
Push-To-Reset, Visi-Rocker  
5
6
Indicate OFF, vertical legend  
Indicate OFF, horizontal legend  
612 12.000  
712 12.500  
613 13.000  
614 14.000  
615 15.000  
616 16.000  
617 17.000  
Push-To-Reset , Single color  
7
8
Vertical legend  
Horizontal legend  
3 POLES2  
1
One  
2
Two  
3
Three  
8 TERMINAL  
7
9
1
2
3
4
5
Stud 10-32  
6
9
Stud M6  
7/16” Clip Terminal  
Plug-In Stud  
8
9
8
8
9,10  
9
4 CIRCUIT  
Screw 10-32  
Stud 1/4-20  
Stud M5 x 0.8  
Screw M5 x 0.8  
B
Series Trip (current)  
A
C
8,10  
5/16” Clip Terminal  
5 AUXILIARY/ALARM SWITCH2  
0
2
3
4
without Aux Switch  
9 ACTUATOR COLOR & LEGEND12  
S.P.D.T., 0.110 Q.C. Term.  
S.P.D.T., 0.139 Solder Lug  
S.P.D.T., 0.110 Q.C. Term.  
(Gold Contacts)  
6
8
9
S.P.S.T., 0.139 Solder Lug  
S.P.S.T., 0.187 Q.C. Term.  
S.P.D.T., 0.187 Q.C. Term.  
Actuator or  
Visi-Color  
Marking:  
Marking Color:  
Single Color  
Rocker/Handle  
Black  
White  
White  
White  
White  
Black  
Black  
11  
Color:  
White  
Black  
Red  
Green  
Blue  
Yellow  
Gray  
Orange  
ON-OFF  
Dual  
Visi-Rocker  
White  
n/a  
Red  
Green  
Blue  
Yellow  
Gray  
Orange  
B
D
G
J
1
2
3
4
5
6
7
8
6 FREQUENCY & DELAY  
11  
12  
14  
16  
21  
22  
24  
DC Ultra Short  
DC Short  
DC Medium  
26  
42  
44  
46  
52  
54  
56  
50/60Hz Long  
4
4
4
4
4
4
50/60Hz Short, Hi-Inrush  
50/60Hz Medium, Hi-Inrush  
50/60Hz Long, Hi-Inrush  
DC Short, Hi-Inrush  
DC Medium, Hi-Inrush  
DC Long, Hi-Inrush  
L
DC Long  
N
Q
S
50/60Hz Ultra Short  
50/60Hz Short  
50/60Hz Medium  
Black  
1
2
3
Notes:  
10 MOUNTING/BARRIERS12  
STANDARD ROCKER BEZEL  
Threaded Insert, 2 per pole  
Push-to-reset actuators have OFF portion of rocker shrouded.  
Multi-pole breakers have all breakers identical except when specifying Aux. switch  
and/or mixed poles, and have one rocker per breaker.  
On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right  
pole.  
15  
BARRIERS  
A
C
6-32 X 0.195 inches  
ISO M3 x 5mm  
yes  
yes  
4
14  
5
6
7
8
9
Available up to 50 amps maximum.  
RECESSED OFF ROCKER  
Current ratings 71 - 100 with VDE approvals are available up to two poles maximum.  
Terminal Code 1 available to 60 amps maximum.  
Threaded Insert, 2 per pole  
6-32 x 0.195 inches  
ISO M3 x 5mm  
E
F
yes  
yes  
Terminal Codes 2, 4, 5 & C available to 50 amps maximum.  
Terminal Codes 3, 6, 9 & A available to 100 amps maximum.  
13  
PUSH-TO-RESET BEZEL  
10 Terminal Codes 9 & C are not VDE approved.  
11 Color shown is visi and legend with remainder of rocker black  
12 Dual = ON-OFF/I-O legend on actuator.  
Threaded Insert, 2 per pole  
6-32 x 0.195 inches  
ISO M3 x 5mm  
B
D
yes  
yes  
13 VDE and TUV approval requires Dual (I-O, ON-OFF) markings on rocker.  
14 Legend on push-to-reset bezel/shroud is white when single color rocker is ordered.  
Legend on push-to-reset bezel/shroud matches visi-color of rocker with actuator  
codes  
11 MAXIMUM APPLICATION RATING  
15 5 & 6.  
A
B
C
D
F
K
M
65 DC  
16 Recessed “OFF-SIDE” available with actuator codes 1, 2, 3, & 4. Legends on rocker  
are available in ink stamping only.  
125 DC  
120/240 AC  
240 AC  
277 AC  
120 AC  
80 DC  
16  
17 Barriers supplied on multi-pole units only.  
18 2 & 3 pole circuit breakers required for 120/240 AC rating.  
12 AGENCY APPROVAL  
A
Gꢀꢀ  
Jꢀꢀ  
without approvals  
ULꢀ489ꢀListedꢀ&ꢀCSAꢀCertified  
UL489ꢀListed,ꢀCSAꢀCertifiedꢀ&ꢀTUVꢀCertified  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
16  
C-Series Handle – Circuit & Terminal Diagrams  
.960 [24.38]  
.311 DIA [Ø7.90]  
.558 [14.17]  
Notes:  
1
2
3
All dimensions are in inches [millimeters].  
Toleranceꢀ±.020ꢀ[.51]ꢀunlessꢀotherwiseꢀspecified.  
Available on Series Trip and Switch Only Circuits when called for on multi-pole units.  
Onlyꢀoneꢀaux.ꢀswitchꢀisꢀnormallyꢀsupplied,ꢀasꢀviewedꢀinꢀmulit-poleꢀidentificationꢀscheme.  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
C-Series Handle – Circuit & Terminal Diagrams  
17  
Notes:  
1
2
3
4
All dimensions are in inches [millimeters].  
Toleranceꢀ±.020ꢀ[.51]ꢀunlessꢀotherwiseꢀspecified.  
Schematic shown represents current trip circuits.  
Available only as special catalog number.  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
18  
C-Series Handle – Form & Fit Drawings  
Notes:  
1
2
All dimensions are in inches [millimeters].  
Toleranceꢀ±.020ꢀ[.51]ꢀunlessꢀotherwiseꢀspecified.  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
C-Series Handleguard – Form & Fit Drawings  
19  
Notes:  
1
2
All dimensions are in inches [millimeters].  
Toleranceꢀ±.020ꢀ[.51]ꢀunlessꢀotherwiseꢀspecified.  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
20  
C-Series Arc Chute Barrier UL Recognized/Listed – Form & Fit Drawings  
Notes:  
1
Onlyꢀ1-poleꢀandꢀ3-poleꢀconfigurationsꢀshown.ꢀArcꢀchuteꢀ(w/oꢀbarrier)ꢀandꢀarcꢀchuteꢀꢀ  
barrier also available for 2-pole construction.  
2
3
Dimensions apply to all variations shown.  
Notice that line and load terminal orientation for indicate on and indicate off rocker  
circuit breakers are opposite.  
4
5
6
7
Screw type terminals shown for Rocker style (CF1, C11, etc) circuit breakers. For  
otherꢀterminalꢀconfigurationsꢀseeꢀcircuitꢀandꢀterminalꢀdiagrams.  
All dimensions are in inches [millimeters].  
Toleranceꢀ±ꢀ.020ꢀunlessꢀotherwiseꢀspecified.  
Must be ordered under a special catalog number.  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
C-Series Parallel Pole – Form & Fit Drawings  
21  
Notes:  
1
2
All dimensions are in inches [millimeters].  
Toleranceꢀ±.020ꢀ[.51]ꢀunlessꢀotherwiseꢀspecified.  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
22  
C-Series Sealed Toggle – Form & Fit Drawings  
Notes:  
1
2
All dimensions are in inches [millimeters].  
Toleranceꢀ±.020ꢀ[.51]ꢀunlessꢀotherwiseꢀspecified.  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
C-Series Rocker – Circuit & Terminal Diagrams  
23  
Notes:  
1
2
3
All dimensions are in inches [millimeters].  
Toleranceꢀ±.020ꢀ[.51]ꢀunlessꢀotherwiseꢀspecified.  
Schematic shown represents current trip circuit.  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
24  
C-Series Rocker – Form & Fit Drawings  
Notes:  
1
2
3
4
Dimensions apply to all variations shown. Notice that circuit breaker line and load terminal orientation on indicate OFF is opposite of indicate ON.  
For pole orientation with horizontal legend, rotate front view clockwise 90°.  
All dimensions are in inches [millimeters].  
Toleranceꢀ±.020ꢀ[.51]ꢀunlessꢀotherwiseꢀspecified.  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
C-Series Flat Rocker – Form & Fit Drawings  
25  
Notes:  
1
2
3
For pole orientation with horizontal legend, rotate front view clockwise 90°.  
All dimensions are in inches [millimeters].  
Toleranceꢀ±.020ꢀ[.51]ꢀunlessꢀotherwiseꢀspecified.  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
26  
Reps & Contact  
Authorized Sales Representatives  
Click on the group name on the map below to find your local representative or visit  
www.carlingtech.com/findarep.  
Matera  
W. Canada  
Matera  
E. Canada  
MIDWEST  
DM  
MichigaNn ORTHERN  
TEMCO Northwest  
ND  
SD  
WA  
OR  
Hanna Lind Ltd.  
MT  
ME  
VT  
WI  
Sierra  
MN  
Melody  
NH  
Emery  
MI  
LD. Allen MA  
ID  
Norris  
NY  
CT  
WY  
«
IA  
IN  
DM Assoc  
OH East  
PA  
RI  
Bridge Marketing  
NE  
KS  
Pacent  
Omega Limited  
Dy-tronix Inc.  
DM  
NJ  
NV  
IL  
TSI North  
DE  
Assoc  
WV  
MD  
TSI  
UT  
CO  
KY  
VA  
CA  
MO  
TN  
NC  
SC  
Luscombe  
Signal  
OK  
Engineering  
WEST  
Enterprises  
AR  
Pinnacle Marketing  
AZ  
NM  
Sunbelt Components  
MS  
AL  
GA  
TX  
SOUTHEAST  
LA  
Matrix  
DM Mexico  
South America  
Mexico  
ProRep  
Solutions  
FL  
LATIN AMERICA  
Europe  
Middle East  
Africa  
Asia-Pacific  
Oceania  
Americas  
About Carling  
Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches  
and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power  
distribution systems. With four ISO registered manufacturing facilities and technical sales offices worldwide,  
Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical  
components, they engineer powerful solutions! To learn more about Carling please visit  
www.carlingtech.com/company-profile.  
To view all of Carling’s environmental, quality, health & safety certifications please visit  
www.carlingtech.com/environmental-certifications  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
Notes  
27  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
Worldwide Headquarters  
Carling Technologies, Inc.  
60 Johnson Avenue, Plainville, CT 06062  
Phone: 860.793.9281 Fax: 860.793.9231  
@
Email: sales carlingtech.com  
@
Northern Region Sales Office: nrsm carlingtech.com  
@
Southeast Region Sales Office: sersm carlingtech.com  
@
Midwest Region Sales Office: mrsm carlingtech.com  
@
West Region Sales Office: wrsm carlingtech.com  
@
Latin America Sales Office: larsm carlingtech.com  
Asia-Pacific Headquarters  
Carling Technologies, Asia-Pacific Ltd.,  
Kowloon, Hong Kong  
Phone: Int + 852-2737-2277 Fax: Int + 852-2736-9332  
@
Email: sales carlingtech.com.hk  
@
Shenzhen, China: shenzhen carlingtech.com  
@
Shanghai, China: shanghai carlingtech.com  
@
Pune, India: india carlingtech.com  
@
Kaohsiung, Taiwan: taiwan carlingtech.com  
@
Yokohama, Japan: japan carlingtech.com  
|
|
Europe Middle East Africa Headquarters  
Carling Technologies LTD  
4 Airport Business Park, Exeter Airport,  
Clyst Honiton, Exeter, Devon, EX5 2UL, UK  
Phone: Int + 44 1392.364422 Fax: Int + 44 1392.364477  
@
Email: ltd.sales carlingtech.com  
@
Germany: gmbh carlingtech.com  
@
France: sas carlingtech.com  
www.carlingtech.com  
REV_08_2015  

相关型号:

CA3-B0-24-425-12C-C

MAGNETIC CIRCUIT BREAKER,
Carling Techn

CA3-B0-24-425-462-CG

MAGNETIC CIRCUIT BREAKER,
Carling Techn

CA3-B0-24-610-522-E

MAGNETIC CIRCUIT BREAKER,
Carling Techn

CA3-B0-24-615-12C-D

Magnetic Circuit Breaker,
Carling Techn

CA3-B0-24-625-32C-C

Magnetic Circuit Breaker,
Carling Techn

CA3-B0-24-640-121-C

Magnetic Circuit Breaker,
Carling Techn

CA3-B0-24-640-321-CG

MAGNETIC CIRCUIT BREAKER,
Carling Techn

CA3-B0-26-617-12C-R

MAGNETIC CIRCUIT BREAKER,
Carling Techn

CA3-B0-26-620-16A-C

MAGNETIC CIRCUIT BREAKER,
Carling Techn

CA3-B0-26-625-511-C

MAGNETIC CIRCUIT BREAKER,
Carling Techn

CA3-B0-26-640-3B1-L

MAGNETIC CIRCUIT BREAKER,
Carling Techn

CA3-B0-34-624-121-D

MAGNETIC CIRCUIT BREAKER,
Carling Techn